Abstract
AIMS
In patients with atrial fibrillation prescribed dabigatran, the aim was to examine the correlation between plasma dabigatran concentrations and the three screening coagulation assays [international normalized ratio (INR), activated partial thromboplastin time (aPTT) and thrombin time (TT)] as well as the dilute thrombin time (dTT) and to examine the contribution of plasma fibrinogen concentrations to the variability in TT results.
METHODS
Plasma from patients with atrial fibrillation on dabigatran were analysed for clotting times and concentrations of fibrinogen and dabigatran. Correlation plots (and associated r(2) values) were generated using these data. The variability in TT results explained by fibrinogen concentrations was quantified using linear regression.
RESULTS
Fifty-two patients (38-94 years old) contributed 120 samples, with plasma dabigatran concentrations ranging from 9 to 408 g l(-1). The r(2) values of INR, aPTT, TT and dTT against plasma dabigatran concentrations were 0.49, 0.54, 0.70 and 0.95, respectively. Plasma fibrinogen concentrations explained some of the residual variability in TT values after taking plasma dabigatran concentrations into account (r(2) = 0.12, P = 0.02).
CONCLUSIONS
Of the screening coagulation assays, the TT correlated best with plasma dabigatran concentrations. Variability in fibrinogen concentrations accounts for some of the variability in the TT.