Influence of implant framework and mandibular flexure on the strain distribution on a Kennedy class II mandible restored with a long-span implant fixed restoration: a pilot study
Journal article   Peer reviewed

Influence of implant framework and mandibular flexure on the strain distribution on a Kennedy class II mandible restored with a long-span implant fixed restoration: a pilot study

Constance Law, Vincent Bennani, Karl Lyons and Mike Swain
The Journal of prosthetic dentistry, Vol.112(1), pp.31-37
01/07/2014
Handle:
https://hdl.handle.net/10523/30187

Abstract

Bicuspid Biomechanical Phenomena Bite Force Chromium Alloys - chemistry Dental Implants Dental Materials - chemistry Dental Prosthesis, Implant-Supported Denture Design Denture, Partial, Fixed Humans Jaw, Edentulous, Partially - physiopathology Jaw, Edentulous, Partially - rehabilitation Mandible - physiopathology Models, Anatomic Molar Osseointegration - physiology Pilot Projects Pliability Stress, Mechanical Titanium - chemistry