Abstract
Introduction: Elevated troponin, while essential for diagnosing myocardial infarction, can also be present in non-myocardial infarction conditions. The myocardial-ischaemic-injury-index (MI3) algorithm is a machine learning algorithm that considers age, sex and cardiac troponin I (TnI) results to risk-stratify patients for type 1 myocardial infarction.
Method: Patients aged ≥25 years who presented to the emergency department (ED) of Singapore General Hospital with symptoms suggestive of acute coronary syndrome with no diagnostic 12-lead electrocardiogram (ECG) changes were included. Participants had serial ECGs and high-sensitivity troponin assays performed at 0, 2 and 7 hours. The primary outcome was the adjudicated diagnosis of type 1 myocardial infarction at 30 days. We compared the performance of MI3 in predicting the primary outcome with the European Society of Cardiology (ESC) 0/2-hour algorithm as well as the 99th percentile upper reference limit (URL) for TnI.
Results: There were 1351 patients included (66.7% male, mean age 56 years), 902 (66.8%) of whom had only 0-hour troponin results and 449 (33.2%) with serial (both 0 and 2-hour) troponin results available. MI3 ruled out type 1 myocardial infarction with a higher sensitivity (98.9, 95% confidence interval [CI] 93.4–99.9%) and similar negative predictive value (NPV) 99.8% (95% CI 98.6–100%) as compared to the ESC strategy. The 99th percentile cut-off strategy had the lowest sensitivity, specificity, positive predictive value and NPV.
Conclusion: The MI3 algorithm was accurate in risk stratifying ED patients for myocardial infarction. The 99th percentile URL cut-off was the least accurate in ruling in and out myocardial infarction compared to the other strategies.