Logo image
Use of a smartphone-based, non-mydriatic fundus camera for patients with red flag ophthalmic presentations in a rural general practice
Journal article   Open access   Peer reviewed

Use of a smartphone-based, non-mydriatic fundus camera for patients with red flag ophthalmic presentations in a rural general practice

Scott Davidson, Waldir Rodrigues de Souza Jr. and Kyle Eggleton
Journal of primary health care, Vol.17(1), pp.4-9
21/05/2024
Handle:
https://hdl.handle.net/10523/50089

Abstract

direct ophthalmoscope fundoscopy fundus photo ophthalmology optic nerve retina rural general practice
Introduction: Fundus examination by direct ophthalmoscopy is widely used in general practice; however, it offers limited field of view, requires close approximation to the patient, has a steep learning curve and is a difficult skill to master and maintain. Non-mydriatic fundus photography (NMFP) offers an alternative with a wider field of view, ability for image analysis and transmission, and is able to be conducted by allied healthcare staff. Aim This study aimed to compare the use of direct ophthalmoscopy with smart-phone NMFP in a large rural general practice. It also aimed to analyse the number of adequate views and positive findings achieved with each instrument and the impact of NMFP on ophthalmology referral decisions. Methods: Patients aged >= 16 years presenting to Dargaville Medical Centre (Dargaville, New Zealand) with visual disturbance, headache, hypertensive urgency (systolic blood pressure (BP) >200 mmHg or diastolic BP >120 mmHg), transient ischemic attack (TIA) or stroke were enrolled prospectively into an observational study of visualisation, diagnosis and management impact for a 1-year period (n = 152, 304 eyes). Direct ophthalmoscopy findings and management plans were documented by the attending general practitioner (GP), and then again following assessment of the NMFP. Results: NMFP significantly improved visualisation of the fundal structures with an increase in adequate views achieved of both the optic disc and the retina. Inter-rater agreement between the referring GP and ophthalmologist was good. Discussion: The use of NMFP in general practice might result in greater accuracy in diagnosing retina and optic disc disease. Routine transmission of NMFP images to specialist eye clinics as part of the referral might improve management and result in health system efficiencies.
pdf
hc24040830.74 kBDownloadView
Published (Version of record)CC BY-NC-ND V4.0 Open Access
url
https://doi.org/10.1071/HC24040View
Published (Version of record)CC BY-NC-ND V4.0 Open

Metrics

Details

Logo image